Bookbot

Awwa

    Awwa C703-19 Cold-Water Meters--Fire-Service Type
    2020 Awwa Compensation Survey: Large Water & Wastewater Utilities
    Awwa C301-14(r19) Prestressed Concrete Pressure Pipe, Steel-Cylinder Type
    Awwa C700-20 Cold-Water Meters--Displacement Type, Metal Alloy Main Case
    2020 Awwa Compensation Survey: Medium-Sized Water & Wastewater Utilities
    Awwa C750-19 Transit-Time Flowmeters in Full Closed Conduits
    • The purpose of this standard is to establish criteria for the establishment of a formal utility water conservation and efficiency program for utilities that wish to implement such a program under this standard. This standard can be referenced in the development and evaluation of water utility conservation and efficiency programs. Major revisions made to the standard include updating of the title and multiple sections to include the terminology water conservation "and efficiency"; new requirement for water shortage or drought plan; updated requirements related to metering, rate structures, and billing; a new section related to landscape transformations; updated current utility requirements related to water audit, validation, and public availability; new section to reflect integration of water efficiency into land-use planning, clarified that wholesale agency requirements should be appropriate and consistent with governing authorities; and updated documentation to ensure correspondence with new requirement sections that were added.

      Awwa G480-20 Water Conservation and Efficiency Program Operation and Management2021
    • The purpose of this standard is to provide the minimum requirements for reduced-wall, resilient-seated gate valves for water supply service, including application, materials, design, testing, inspection, rejection, marking, and shipping. This standard can be referenced in specifications for purchasing and receiving reduced-wall, resilient-seated gate valves for water supply service. The stipulations of this standard apply when this document has been referenced and then only to reduced-wall, resilient-seated gate valves for water supply service. The valves encompassed by this standard require considerations for compatibility with the material being conveyed from both chemical and physical perspectives. Wastewater implies a lack of control over its chemical and physical composition. Valves in compliance with this standard may be suitable for wastewater applications; however, compliance does not ensure manufacturer approval of a specific valve in wastewater applications. Suitability for a specific valve should be determined by analyzing a particular wastewater application in conjunction with the manufacturer.

      Awwa C515-20 Reduced-Wall, Resilient-Seated Gate Valves for Water Supply Service2021
    • The purpose of this standard is to provide the minimum requirements for online chlorine analyzer O&M, sampling requirements, accuracy and precision testing requirements, range requirements, and methods of calibration and troubleshooting. This standard can be referenced in documents for purchasing online chlorine analyzers, can be used as a guide for verifying the accuracy and precision of online chlorine analyzers, or can assist utilities in establishing online chlorine analyzer O&M procedures. The user should ensure the environmental conditions of the application match the manufacturer-specified conditions and requirements for the analyzer. The stipulations of this standard apply when this document has been referenced, and then only to online chlorine analyzers used in the treatment and monitoring of potable water, reclaimed water, or wastewater.

      Awwa C670-20 Online Chlorine Analyzer Operation and Maintenance2021
    • Awwa C950-20 Fiberglass Pressure Pipe

      • 28 páginas
      • 1 hora de lectura

      The purpose of this standard is to provide the minimum requirements for fiberglass pressure pipe, including design, fabrication, and testing requirements. This standard can be referenced in specifications for purchasing and receiving fiberglass pressure pipe. This standard can be used as a guide for manufacturing this type of fiberglass pressure pipe. The stipulations of this standard apply when this document has been referenced and then only to fiberglass pressure pipe.

      Awwa C950-20 Fiberglass Pressure Pipe2021
    • The purpose of this standard is to provide the minimum requirements for sacrificial anode cathodic protection systems for the interior submerged surfaces of steel water storage tanks, including design, system components, quality of work, installation, operation, and maintenance. This standard can be referenced in specifications for designing and installing sacrificial anode cathodic protection systems for the interior submerged surfaces of steel water storage tanks. The stipulations of this standard apply when referenced and then only to sacrificial anode cathodic protection systems for the interior submerged surfaces of steel water storage tanks.

      Awwa D106-20 Sacrificial Anode Cathodic Protection Systems for the Interior Submerged Surfaces of Steel Water Storage Tanks2021
    • The purpose of this standard is to provide the requirements for materials, testing, inspection, and shipping of PE pipe (3/4 in. [19 mm] through 3 in. [76 mm]) and PE tubing (3/4 in. [19 mm] through 2 in. [51 mm]) for potable water, wastewater, and reclaimed water systems. This standard can be referenced when purchasing and receiving PE pressure pipe and tubing for use in potable water, wastewater, and reclaimed water systems. This standard can be used as a guide for manufacturing this type of pressure pipe and tubing. The stipulations of this standard apply when this document has been referenced and then only to 3/4-in. (19-mm) through 3-in. (76-mm) PE pipe and 3/4-in. (19-mm) through 2-in. (51-mm) tubing for potable water, wastewater, and reclaimed water service.

      Awwa C901-20 Polyethylene (Pe) Pressure Pipe and Tubing, 3/4 In. (19 MM) Through 3 In. (76 MM), for Water Service2021
    • Make sound salary decisions for your utility. Compare your utility's salaries to those of similar utilities by filtering data. Reference salary range minimum, mid-point, and maximum levels for each position as well as 50th percentile, company-weighted average pay, and employee-weighted average pay.

      2020 Awwa Compensation Survey: Medium-Sized Water & Wastewater Utilities2020
    • The purpose of this standard is to provide the minimum requirements for cold-water meters--displacement type, metal alloy main case, including materials and design. This standard can be referenced in specifications for purchasing and receiving cold-water meters--displacement type, metal alloy main case. This standard can be used as a guide for manufacturing this type of meter. The stipulations of this standard apply when this document has been referenced and only to cold-water meters--displacement type, metal alloy main case.

      Awwa C700-20 Cold-Water Meters--Displacement Type, Metal Alloy Main Case2020
    • The purpose of this standard is to provide the minimum requirements for manufacturing steel-cylinder-type prestressed concrete pressure pipe. This standard can be referenced in specifications for purchasing and receiving prestressed concrete pressure pipe, steel-cylinder type, and can be used as a guide for manufacturing this type of concrete pressure pipe. The stipulations of this standard apply when this document has been referenced in relation to prestressed concrete pressure pipe, steel-cylinder type.

      Awwa C301-14(r19) Prestressed Concrete Pressure Pipe, Steel-Cylinder Type2020
    • Make sound salary decisions for your utility. Compare your utility's salaries to those of similar utilities by filtering data. Reference salary range minimum, mid-point, and maximum levels for each position as well as 50th percentile, company-weighted average pay, and employee-weighted average pay.

      2020 Awwa Compensation Survey: Large Water & Wastewater Utilities2020
    • This standard covers the various types and classes of cold water fire service type meters in sizes 3 in. (80 mm) through 10 in. (250 mm) and the materials and workmanship used in their fabrication. A fire-service meter shall consist of one of the following: A combination of (1) a mainline meter of the turbine type (Class II), either Underwriters Laboratories listed or Factory Mutual Research approved; (2) either a UL-listed or an FM-approved fire-service strainer; (3) a bypass meter of the appropriate size for measuring low flow rates; and (4) an automatic valve for diverting flow rates other than fire demand through the bypass meter. A combination of (1) a mainline meter of the turbine type (Class II), either UL listed or FM approved; and (2) either a UL-listed or an FM-approved fire-service strainer. Major revisions to this edition of C703 include the following: Type I devices, proportional fire-service meters with check valve, are no longer addressed in this standard Information is provided on lead content criteria and recent federal legislation revising the definition of "lead free" in the Safe Drinking Water Act. The definition of manufacturer has been changed. The materials have been updated in response to legislation revising the definition of "lead free" in the Safe Drinking Water Act. The section on registers has been updated to include requirements for electronic display registers.

      Awwa C703-19 Cold-Water Meters--Fire-Service Type2020
    • The purpose of this standard is to provide the minimum requirements for cold-water meters--displacement type, plastic main case, including materials and design. This standard can be referenced in specifications for purchasing and receiving cold-water meters--displacement type, plastic main case. This standard can be used as a guide for manufacturing this type of meter. The stipulations of this standard apply when this document has been referenced and only to cold-water meters--displacement type, plastic main case.

      Awwa C710-20 Cold-Water Meters--Displacement Type, Plastic Main Case2020
    • Make sound salary decisions for your utility. Compare your utility's salaries to those of similar utilities by filtering data. Reference salary range minimum, mid-point, and maximum levels for each position as well as 50th percentile, company-weighted average pay, and employee-weighted average pay.

      2020 Awwa Compensation Survey: Small Water & Wastewater Utilities2020
    • This standard describes the various types and classes of cold-water singlejet meters in sizes 5/8 in. (15 mm) through 6 in. (150 mm) for water utilities' customer service and the materials and workmanship employed in their fabrication. These meters register by recording the revolutions of a rotor powered by the force of flowing water striking its blades.

      Awwa C712-19 Cold-Water Meters - Singlejet Type2020
    • The purpose of this standard is to define the minimum requirements for the disinfection of water treatment plants, including facility preparation, application of chlorine to the interior surfaces of water treatment units, and sampling and testing for the presence of total coliform bacteria. This standard can be referenced in specifications for the disinfection of water treatment plants and can be used as a guide for facility preparation, application of chlorine, and sampling and testing for the presence of total coliform bacteria. The stipulations of this standard apply when this document has been referenced and then only to the disinfection of water treatment plants.

      Awwa C653-20 Disinfection of Water Treatment Plants2020
    • Prestressed concrete cylinder pipe (PCCP) is used principally in the transmission and distribution of water in municipal, industrial, and irrigation systems. It is also used in plant piping systems, seawater cooling systems, sewer force mains, and gravity sewers. Other applications include inverted siphons, liners for pressure tunnels, and culverts with high earth covers.

      Awwa C304-14(r19) Design of Prestressed Concrete Cylinder Pipe2020
    • This standard describes transit-time ultrasonic flowmeters for water supply service application in pipes running full. An ultrasonic flowmeter is a meter that uses acoustic energy signals to measure liquid velocity. There are currently two distinct types of ultrasonic flowmeters available: Doppler-effect and transit-time. The Doppler-effect meter is used exclusively for liquids containing solid particles or gases, and the transit-time flowmeter is used in a wide variety of applications in the water industry.

      Awwa C750-19 Transit-Time Flowmeters in Full Closed Conduits2020
      4,0
    • This standard reflects a committee consensus of industry practice concerning the design, detailing, and construction of prestressed-concrete water tanks that employ horizontal prestressing tendons in walls. This standard also addresses the use of prestressing tendons in floors, vertically in the walls, and in roofs. Recommended criteria and guidelines are presented to assist engineers in design and construction of both cast-in-place and precast concrete tanks using tendon prestressing, based on the specific detailed experience of the committee members. Engineering principles are tied to existing codes where applicable.

      Awwa D115-20 Tendon-Prestressed Concrete Water Tanks2020
    • This standard for disinfection of water-storage facilities describes materials, facility preparation, application of disinfectant to interior surfaces of facilities, and sampling and testing for the presence of coliform bacteria, chlorine residual, and acceptable aesthetic water quality. The standard also includes disinfection procedures for underwater inspection and/or cleaning of potable-water-storage facilities but does not describe the technical aspects of underwater inspection and/ or cleaning.

      Awwa C652-19 Disinfection of Water Storage Facilities2020